Suunto is committed to achieving Level AA conformance for this website in conformance with the Web Content Accessibility Guidelines (WCAG) 2.0 and achieving compliance with other accessibility standards. Please contact Customer Service at USA +1 855 258 0900 (toll free), if you have any issues accessing information on this website.

Suunto DX User Guide

Technical specifications

Dimensions and weight

  • Length: 49 mm (1.94 in)
  • Width: 49 mm (1.94 in)
  • Height: 17 mm (0.68 in)
  • Weight: 107 g (3.77 oz) (with elastomer bracelet), 182 g (42 oz) (with titanium bracelet)

Operating Instructions

  • Water resistance: 200 m (656 ft) (complying with ISO 6425)
  • Normal altitude range: 0 to 3,000 m (0 to 10,000 ft) above sea level
  • Operating temperature: 0 °C to 40 °C (32 °F to 104 °F)
  • Storage temperature: -20 °C to +50 °C (-4 °F to +122 °F)
  • Maintenance cycle: 200 dives or two years, whichever comes first

Depth gauge

  • Temperature compensated pressure sensor
  • Accurate to 150 m (482 ft) complying with EN 13319
  • Depth display range: 0 to 300 m (0 to 984 ft)
  • Resolution: 0.1 m from 0 to 100 m (1 ft from 0 to 328 ft)

Temperature display

  • Resolution: 1 °
  • Display range: -20 °C to +50 °C (-4 °F to +122 °F)
  • Accuracy: ± 2 °C (± 3.6 °F) within 20 minutes of temperature change

Mixed mode

  • Helium: 0–95%
  • Oxygen: 5–99%
  • Partial pressure of oxygen (pO2): 0.2 – 3.0
  • Oxygen Limit Fraction: 0–200% with 1% resolution
  • Gas mixtures: up to 8

CCR mode

  • Helium %: 0–95
  • Oxygen %: 5–99
  • Partial pressure of oxygen (pO2): 0.2 – 3.0
  • Oxygen Limit Fraction: 0–200% with 1% resolution
  • CC gases: up to 3
  • OC gases: up to 8

Other displays

  • Dive time: 0 to 999 min
  • Surface time: 0 to 99 h 59 min
  • Dive counter: 0 to 999 for repetitive dives
  • No-decompression time: 0 to 99 min (– after 99)
  • Ascent time: 0 to 999 min (– after 999)
  • Ceiling depths: 3.0 to 150 m (10 to 492 ft)

Calendar clock

  • Accuracy: ± 25 s/month (at 20°C/68°F)
  • 12/24 h display

Compass

  • Accuracy: +/- 15°
  • Resolution: 1°
  • Max. tilt: 45 degrees
  • Balance: global

Timer

  • Accuracy: 1 second
  • Display range: 0’00 – 99’59
  • Resolution: 1 second

Logbook

  • Sample rate in air and mixed modes: default 20 seconds
  • Memory capacity: approximately 60 hours with 20-second recording interval and without transmitter data. With transmitter data, the capacity is approximately 40 hours. In free dive mode (2-second recording interval), maximum capacity is 3 hours.

Tissue calculation model

  • Suunto Fused RGBM
  • Maximum depth of operation: 150 m (492 ft)

Radio transceiver

  • Frequency band: single channel 5.3 kHz
  • Maximum output power: 110 mW
  • Range: 1.5 m / 4.9 ft

Manufacturer

Suunto Oy

Tammiston kauppatie 7 A

FI-01510 Vantaa FINLAND

Table of Content