Reference
Technical specifications
Dimensions and weight:
- Length: 53 mm / 2.08 in
- Width: 53 mm / 2.08 in
- Height: 16.5 mm / 10.65 in
- Weight: 90 g / 3.17 oz
Operating conditions
- Normal altitude range: 0 to 3000 m / 9800 ft above sea level
- Operating temperature (diving): 0 °C to +40 °C / +32 °F to +104 °F
- Operating temperature (non-diving): -20 °C to +50 °C / -4 °F to +122 °F
- Storage temperature: -20 °C to +50 °C / -4 °F to +122 °F
- Recommended charging temperature: 0 °C to +35 °C / +32 °F to +95 °F
- Maintenance cycle: 500 hours of diving or two years, whichever comes first
NOTE:
Do not leave the dive computer in direct sunlight!
Depth gauge
- Temperature compensated pressure sensor
- Accurate to 100 m / 328 ft complying with EN 13319 and ISO 6425
- Depth display range: 0 to 300 m / 0 to 984 ft
- Resolution: 0.1 m from 0 to 100 m / 1 ft from 0 to 328 ft
Temperature display
- Resolution: 1 °C / 1.5 °F
- Display range: -20 °C to +50 °C / -4 °F to +122 °F
- Accuracy: ± 2 °C / ± 3.6 °F within 20 minutes of temperature change in temperature range of 0 °C to +40 °C / +32 °F to +104 °F.
Displays in Air/Nitrox dive mode
- Oxygen %: 21–99
- Oxygen partial pressure display: 0.0–3.0 bar
- CNS%: 0–500% with 1% resolution
- OTU: 0–1000
Other displays
- Dive time: 0 to 999 min
- Surface time: 0 to 99 h 59 min
- Dive counter: 0 to 99 for repetitive dives
- No decompression time: 0 to 99 min (>99 above 99)
- Ceiling depths: 3.0 to 200 m / 9.8 to 656 ft
- Ascent time: 0 to 999 min (>999 after 999)
Calendar clock
- Accuracy: ± 5 s/month (0 °C to 50 °C / 32 °F to 122 °F)
- 12/24 h display
Compass
- Accuracy: ± 15°
- Resolution: 1°
- Max. tilt: 45 degrees
- Balance: global
Timer
- Accuracy: 1 second
- Display range: 0’00–99’59
- Resolution: 1 second
Logbook
- Sample rate: 10 seconds
- Sample rate freedive: 1 second
- Memory capacity: approximately 200 hours of diving or 400 dive logs, whichever comes first
Tissue calculation model
- Suunto Fused™ RGBM 2 algorithm (developed by Suunto and Bruce R. Wienke, BSc, MSc, PhD)
- 15 tissue compartments
- Tissue compartment halftimes for nitrogen: 1, 2, 5, 10, 20, 40, 80, 120, 160, 240, 320, 400, 480, 560 and 720 min. The on-gassing and off-gassing halftimes are the same.
- Reduced gradient (variable) M-values based on diving habit and dive violations. The M-values are tracked up to 100 hours after a dive.
- The exposure calculations (CNS% and OTU) are based on recommendations by R.W. Hamilton, PhD and currently accepted exposure time limit tables and principles.
Battery
The following conditions have an effect on the expected battery lifetime:
Radio transceiver
- Bluetooth® Smart compatible
- Frequency band: 2402–2480 MHz
- Maximum output power: <4 dBm
- Range: ~3 m / 9.8 ft
Underwater radio receiver
- Frequency band: single channel 123 kHz
- Range: 1.4 m / 4.6 ft
Manufacturer
Suunto Oy
Tammiston kauppatie 7 A
FI-01510 Vantaa
FINLAND