Reference
Technical specifications
Dimensions and weight:
- Length: 104.6 mm / 4.12 in
- Width: 60.5 mm / 2.38 in
- Height: 23.1 mm / 0.91 in
- Weight: 347 g / 12.2 oz
Operating conditions
- Normal altitude range: 0 to 3000 m / 9800 ft above sea level
- Operating temperature: 0 °C to +40 °C / +32 °F to +104 °F
- Storage temperature: -20 °C to +50 °C / -4 °F to +122 °F
- Recommended charging temperature: 0 °C to +35 °C / +32 °F to +95 °F
- Maintenance cycle: 500 hours of diving or two years, whichever comes first
NOTE:
Diving in freezing conditions may damage the dive computer. Make sure the device is not getting frozen when wet.
NOTE:
Do not leave the dive computer in direct sunlight!
WARNING:
Do not expose the device to temperatures above or below the given limits, otherwise it might get damaged or you might be exposed to safety risk.
Depth gauge
- Temperature compensated pressure sensor
- Maximum depth of operation: 80 m / 262 ft (complying with EN 13319)
- Maximum static pressure: 15 bar (complying with EN 13319 and ISO 6425)
- Accuracy: ± 1% of full scale or better from 0 to 150 m / 492 ft at 20 °C / 68 °F (complying with EN 13319)
- Depth display range: 0 to 300 m / 984 ft
- Resolution: 0.1 m from 0 to 100 m / 1 ft from 0 to 328 ft; 1 m from 100 to 150 m / 1 ft from 328 to 392 ft
Temperature display
- Resolution: 1 °C / 1.5 °F
- Display range: -20 °C to +50 °C / -4 °F to +122 °F
- Accuracy: ± 2 °C / ± 3.6 °F within 20 minutes of temperature change in temperature range of 0 °C to +40 °C / +32 °F to +104 °F
Displays in mixed gas dive mode
- Helium %: 0–95
- Oxygen %: 5–99
- Oxygen partial pressure display: 0.0–3.0 bar
- CNS%: 0–500% with 1% resolution
- OTU: 0–1000
Other displays
- Dive time: 0 to 999 min
- Surface time: 0 to 99 h 59 min
- Dive counter: 0 to 99 for repetitive dives
- No decompression time: 0 to 99 min (>99 above 99)
- Ascent time: 0 to 999 min (>999 after 999)
- Ceiling depths: 3.0 to 300 m / 10 to 984 ft
Calendar clock
- Accuracy: ± 25 s/month (at 20 °C / 68 °F)
- 12/24 h display
Compass
- Accuracy: ± 15°
- Resolution: 1°
- Max. tilt: 45 degrees
- Balance: global
Timer
- Accuracy: 1 second
- Display range: 0’00–99’59
- Resolution: 1 second
Logbook
- Sample rate: 10 seconds
- Memory capacity: approximately 200 hours of diving or 400 dive logs, whichever comes first
Tissue calculation model
- Suunto Fused™ RGBM 2 algorithm (developed by Suunto and Bruce R. Wienke, BSc, MSc, PhD)
- 15 tissue compartments
- Tissue compartment halftimes for nitrogen: 1, 2, 5, 10, 20, 40, 80, 120, 160, 240, 320, 400, 480, 560 and 720 min. The on-gassing and off-gassing halftimes are the same.
- Tissue compartment halftimes are divided by a constant factor to obtain helium halftimes.
- Reduced gradient (variable) M-values based on diving habit and dive violations. The M-values are tracked up to 100 hours after a dive
- The exposure calculations (CNS% and OTU) are based on recommendations by R.W. Hamilton, PhD and currently accepted exposure time limit tables and principles.
Battery
- Type: 3.7 V rechargeable lithium-ion
- Charging: USB: 5 Vdc, 0.8 A
- Battery life: fully charged, min. 20 h dive time
The following conditions have an effect on the expected battery lifetime:
- The conditions in which the unit is operated and stored (for example, temperature/cold conditions). Below 10 °C / 50 °F the expected battery lifetime is about 50–75% of that at 20 °C / 68 °F.
- The quality of the battery. Some lithium batteries may exhaust unexpectedly, which cannot be tested in advance.
NOTE:
Rechargeable batteries have a limited number of charge cycles and may eventually need to be replaced. Do not try to replace the battery by yourself! It should always be replaced by an authorized Suunto Service Center.
NOTE:
Low temperature may activate the battery warning even though the battery has enough capacity for diving in water with higher temperatures (40 °C or less).
Radio transreceiver
- Bluetooth® Smart compatible
- Frequency band: 2402–2480 MHz
- Maximum output power: <4 dBm
- Range: ~3 m / 9.8 ft
Underwater radio receiver
- Frequency band: single channel 123 kHz
- Range: 1.5 m / 4.9 ft
Manufacturer
Suunto Oy
Tammiston kauppatie 7 A
FI-01510 Vantaa
FINLAND